Applicable version9.0.2.3
PrecautionsAfter the software is updated, the system will automatically reorganize (it will be reopened twice) for about 3 to 5 minutes.
====※ System settings ※Basic settings →(01) Adjustment: [General Settings]> "Auto VPN" to add "compatibility mode" function settings, support the old version of Auto VPN connection.(02) Amendment: [Management interface access settings]> "Management interface how long to automatically disconnects" part of the situation.
Time setting →Amendment: When "Time Zone" selects "ASIA/Riyadh", it will cause the problem of [Backup and Restore> System Backup].
Administrator → -Amendment: [USB Record Backup] PHP error may occur due to a large amount of information.
Backup and restore →Amendment: "Restore the preset value of the factory" that does not correctly restore the voucher information.
Message notification →Amendment: The issue of the situation of "line disconnection" is not notified.
AP management →(01) New: Support AP model WAX620D-6E, NWA50-AX-PRO, NWA130BE, NWA90-AX-PRO.(02) New: [AP Management] Support 6GHz Channel settings.(03) New: [AP Management] Support "802.11 K/V ROAMING" function settings.(04) Amendment: [AP Management] Some situations "online people" did not display the problem correctly.(05) Amendment: [AP Management]> "Delivery Settings" part of the situation of the setting of delivery failure.(06) Amendment: Some NWA series AP controls the problem of abnormal control function after the device is updated.
※ Network settings ※ Network interface →(01) Adjustment: [IPv6] RADVD, DHCPV6 function is unified in [Internet Service> DHCP] settings.(02) Adjustment: [WIFI]> "Bridge" When switching settings, when selecting the "Re -Starting System", the settings will not be stored. (*Wifi)(03) Amendment: When the interface is set to DHCP, the problem of "DHCP lease expiration date" is not displayed.(04) Activity: Different interfaces "MAC address" can still be stored when repeatedly set.
Route management →(01) Amendment: [Exit Line] [New/Edit]> "Line detection method" is set to display disconnection after being stored.(02) Amendment: [Exit Line] [New/Edit]> "Interface" and "Line Detection Method" are also set to be unable to store when NONE.(03) Amendment: [Exit Line] [New/Edit]> "Interface" lacks the problem of the IP TUNNEL interface.(04) Amendment: [Exit line] The problem that the status is not changed when the situation is broken.(05) Amendment: [Exit Line] After editing, it will cause the related [Exit Line Group] to be displayed as a disconnected problem.(06) Amendment: [Exit line group group] When part of the situation of the situation, the back end does not operate correctly.(07) Amendment: [Exit Line Group] [New Zeng/Edit]> "Load Balance Mode" is set to "interface load load small preferential selection" mode, and some of the control rules applied in some cases will be abnormal.
Vlan (802.1Q) →(01) New: [Added/Edit]> "Access Control": "HTTPS" function settings.(02) Amendment: When the [Delete] is performed, the interface has not been promoted in the IPv6 regulations.
PPPOE dial →(01) Amendment: [New/Edit] When the password uses the '#' character element, it will cause the connection failure.(02) Amendment: [Edit] When the line is discontinued, the relevant connection settings are not determined correctly.(03) Amendment: When [Delete] is executed in part, the problem of information errors is prompted.
Wwan dial →Amendment: After using the E3372H mobile network card, set the problem of failure to detect the failure of the [Exit Line] line detection.
Ip tunnel →(01) Amendment: The problem of obtaining information through the TUNNLE line obtains information failure.(02) Amendment: When using the encrypted mode IPSEC connection, the "key" at both ends can still be connected.
Interrupt settings →New: [Hard interrupt settings]> [Enable interrupt data loading] function button to display instant interrupt data.
※ Regulations ※Control rules →(01) New: [Added/Edit]> "Source Network/Destination Network" increases the query function.(02) New increase: In the list of rules list, "the maximum number of the maximum lines that each source IP can use" can be click to view the blocking record.(03) Amendment: [Newly added/Edit]> "Application Development" After the use of rapid settings, there are problems that have not been prompted correctly when there are functional conflicts.(04) Amendment: [New/Edit] When storage setting in part of the situation, the problem of error prompts that the source/destination network and the interface do not meet.(05) Amendment: [Newly Added/Edit]> "Advanced Settings"> "Timetable" setting, part of the situation does not be controlled according to time.(06) Amendment: [Advanced] [Newly added/Edit]> "Source Interface" lacks the problem of the IP TUNNEL interface.(07) Amendment: [External to internal/Advanced] [New/Edit] When "SMTP Records: Nearly", the email service is abnormal.(08) Amendment: The TIP information of "URL Management" in the rule list shows incorrect problems.(09) Amendment: When the situation is set to block the specified source MAC, the problem that cannot be correctly blocked.(10) Amendment: When the regulations apply the PPPOE to the exit line and interrupt, the problem of losing the packet into the preset routing will be mistaken.(11) Amendment: When the DDOS attack source packet is blocked through the regulations, the problem of equipment load is still incurred.
IPSEC control →(01) New: [Added/Edit]> "Source Network/Destination Network" increases the query function.(02) Adjustment: [New Zeng/Edit] "Source Network/Destination Network" can choose a list of [address table] and [address table group].
SD-WAN control →(01) New: [Added/Edit]> "Source Network/Destination Network" increases the query function.(02) Adjustment: [New Zeng/Edit] "Source Network/Destination Network" can choose a list of [address table] and [address table group].(03) Adjustment: [Newly added/edit]> "Advanced Settings": "SD-WAN" is prohibited from storage settings when selecting NONE.
※ Management goals ※Address table →(01) New: [address table] [New addition/editing]> Setting method: The functional setting of the "external link list" can be obtained for control.(02) New: [Address List] [New/Edit]> "Setting Method" add "IPv6 and Link address" function settings to provide device binding IPv6.(03) New: [Site Table Group Group] Add [Search] function.(04) Adjustment: [Address table]> [Search] IP support string and cover format query.(05) Adjustment: [Address table]> [Auxiliary selection]> [Search] IP support string and cover format query.(06) Amendment: [address table] Mac address setting "00: 00: 00: 00: 00: 00" cannot be stored.(07) Amendment: [IPv6] [address table]> [Site table remittance] After remittance, settings are set incomplete.(08) Amendment: [IPv6] [address table] part of the situation of the abnormal problem of IPv4 and IPv6 interface switching.(09) Amendment: [Site table group group] Set the problem that the address table of the "IP+MAC" type of "IP+MAC" type is set to the group when the regulations cannot be correctly controlled after applying.(10) Amendment: Part of the situation [Regulations of control] The problem of invalidation of the site table settings.
Application control →(01) Adjustment: [New increase/editing] Optimize the setting interface operation.(02) Adjustment: 【New/Edit】> "Data Sharing and Storage: Google Driver" must be paired with other controlsThe project blocks the prompts of the setting. (New Edition App)
URL Management →Amendment: [Records] Some situations of the URL whitelist blocking records show the problem of information errors.
Firewall function →(01) Amendment: [Firewall Function]> The problem of "permanent blockade" that cannot continue to add IP when the number of blocks cannot continue to add.(02) Amendment: [Firewall function]> "Permanent blockade" error blocking the problem of the IP of the machine.(03) Amendment: [Firewall Function]> "Other items": "Block the ping of deth attack" that may be mistaken.(04) Amendment: Part of the case will be wrong to block the IP of this machine, which will cause the management interface to be unable to connect.
Internet authentication →(01) Adjustment: [Users of this machine]> [Import] When repeated accounts, you are allowed to select "replacement" or"Ignore" completes the remittance action.(02) Adjustment: [Users of this machine] [Edit] can modify the setting of the "name" field.(03) Adjustment: [POP3, IMAP, Radius user] [Edit]> [Import] When repeated accounts, you are allowed to select "replace" or "ignore" to complete the remittance action.(04) Adjustment: [POP3, IMAP, Radius user] [Edit]> "server member setting" increase "user account number" sorting function settings.(05) Amendment: [User user] The user password contains a single quotation number (') or dual quotation (").Question.(06) Amendment: [The user of this machine] The "Name/User Account" sets the problem of not checking the length of the string in the field.(07) Amendment: [The user of this machine/POP3, IMAP, RADIUS user] The problem of delete in the account use.(08) Amendment: [POP3, Imap, Radius user]> "Radius server list" partThe situation cannot be deleted.
※ Online service ※DHCP →(01) New: [IPv6] [DHCP Server]> "Interface" Support "VLAN (802.1Q)" interface settingsCertainly.(02) Adjustment: [DHCP server] When setting the "802.1Q" interface, you can specify the IP address of different sections of the same interface as a setting.(03) Amendment: [DHCP Server] Part of the situation on the CLIENT device to obtain DHCP Server information is not the problem of the device's IP.(04) Amendment: [DHCP server]> "Preset gateway" does not follow the problem of connecting the interface IP according to the setting.(05) Amendment: [DHCP Black List MAC address]> "DHCP Flood Attack Protection" function related to the problem of incorrect information.(06) Amendment: The IP in the "DHCP fixed IP address" has been set in some cases.question.
Virus engine →(01) Amendment: [Kaspersky engine] Some situations that cause the management interface to be unable to connect when the service starts.(02) Amendment: [Kaspersky Engine] Some situations that cause the webpage to be incorporated from time to time when the anti -drugs are enabledquestion.(03) Amendment: When the setting of "Sweeping Engine Settings" is set off, the CLAMAV engine is still activated.
Sandstorm →New: Support offline update function, you can upload files to be transferred or uploaded through USB.